Tel: 0121 553 1877
Fax: 0121 553 5507

Albion Structural Framing System (SFS) 
Design Specification

Our sections are manufactured from cold forming pre hot dipped galvanised steel S450 with guaranteed minimum yield strength of 450N/mm2 and a Z275 galvanised coating.

Albion offers non load bearing external wall framing system, infill or continuous, supporting the weight of lightweight claddings and resist lateral wind forces.

Design of the sections to BS5950 Part 5:1998. A load factor of 1.4 is adopted for the load tables.

The load tables (in Albion's Structural Framing System Manual) can be used as a guide to size stud sections. They include spans up to 6m, with a range of deflection criteria from span/200 to span/360.

 

Structural Framing Solutions

Structural Steel Sections

SFS Design Specification
Stud Section Properties
Track Section Properties

Download Brochure

SFS Flyer

Also incorporated are differing types of stud restraint condition from full restraint provided by the cladding system, unrestrained sections and tie restrains provided at mid span.

Although studs are generally fixed at 600mm centres we offer safe loads for additional stud centres of 400,500 and 1000mm.

Steel Framing Solutions SFS


For more information, download our online SFS Brochure. To accompany this, the SFS Flyer includes newly added section sizes.

For additional information contact one of our Sales or Technical. Contact details can be found on the Contact Us page.

 